Terminal

CPX

197330

Product Documentation

Download Datasheet
Spare parts
Spare parts

Product Documentation

Download Datasheet
Configurator is not supported on mobile devices
  • Accessories
  • Technical Data
  • Support / Downloads
Close Technical Data
Show Technical Data
Internal cycle time
< 1 ms
Max. address volume, inputs
64 Byte
Max. address volume, outputs
64 Byte
Diagnosis
Diagnostic memory
Channel-oriented and module-oriented diagnostics
Undervoltage of modules
Parameterisation
Diagnostic behaviour
Fail-safe response
Forcing of channels
Signal setup
LED display
Bus status
Channel status
Module status
System status
Operational voltage range DC
18 V ... 30 V
Nominal operating voltage DC
24 V
Electrical control
Fieldbus
Integrated controller
Max. power supply
16 A
Approval
RCM trademark
c UL us - Recognized (OL)
KC mark
KC-EMV
CE mark (see declaration of conformity)
To EU EMC Directive
To EU Explosion Protection Directive (ATEX)
In accordance with EU RoHS Directive
Explosion protection certification outside the EU
EPL Gc (RU)
Explosion protection
Zone 2 (ATEX)
Zone 2 (RU)
Storage temperature
-20 °C ... 70 °C
ATEX category gas
II 3G
Degree of protection
IP65
IP67
Ambient temperature
-5 °C ... 50 °C
Explosion ignition protection type for gas
Ex nA IIC T4 X Gc
Ex nA IIC T4 X Gc
Explosion ambient temperature
-5°C <= Ta <= +50°C