Commissioning the hardware of YJKP. This tutorial explains, how you assemble the hardware mechanically in the first step – how you insert the SD card, mount the parallel kit, pretension the toothed belt and mount the sensor. This video shows the instruction at a parallel kit as an example. Commission, configure, convert or repair Festo products quickly and easily with videos from service2see.
Chapters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
00:23 Insert SD card
00:50 Mount parallel kit – Mount the base
02:19 Mount parallel kit – Install the toothed belt
06:25 Mount parallel kit – Pretension the toothed belt
07:34 Mount parallel kit – Mount the top
08:12 Mount sensor
Commissioning the hardware of YJKP. This tutorial explains, how you commission the hardware electrically in the second step – how you wire the controller CMMP and the controller CECC-X. This video shows the instruction at a YJKP-1,5 (force class 1.5 kN) and the control highness “WebVisu” as an example.
Commission, configure, convert or repair Festo products quickly and easily with videos from service2see.
Chapters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
00:30 Wire the CMMP
00:38 CMMP | X90
1:43 CMMP | X1
02:11 CMMP | X40
02:49 CMMP | X18
03:09 CMMP | X4
03:34 CMMP | X2B
04:00 CMMP | X6
04:30 Wire the CECC-X
04:39 CECC-X | X8
05:05 CECC-X | X1
05:36 CECC-X | X5
06:07 CECC-X | X19
06:38 CECC-X | X3
07:14 CECC-X | X17
07:45 CECC-X | X20
Use “WebVisu” to commission the Festo servo press kit YJKP. This tutorial explains, how to prepare everything in order to access the interface of “WebVisu” in the first step. Therefore, download the configuration and software package of the servo press kit and set up the network using the Festo field device tool. This video shows the instruction at a YJKP-1,5 (force class 1.5 kN) and the control highness (master control) “WebVisu” as an example.
Commission, configure, convert or repair Festo products quickly and easily with videos from service2see.
Chapters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
00:17 Downloading the configuration package
01:34 Setting up the network
Use “WebVisu” to commission the Festo servo press kit YJKP. This tutorial explains, how to access the interface of “WebVisu”, in order to configure the hardware and carry out homing in the second step. This video shows the instruction at a YJKP-1,5 (force class 1.5 kN) and the control highness (master control) “WebVisu” as an example.
Commission, configure, convert or repair Festo products quickly and easily with videos from service2see.
Chapters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
00:15 Starting “WebVisu”
01:04 Configuring the hardware 02:37 Carrying out homing
Use “WebVisu” to commission the Festo servo press kit YJKP. This tutorial explains, how to create and start an easy program in the third step. This video shows the instruction at a YJKP-1,5 (force class 1.5 kN) and the control highness (master control) “WebVisu” as an example.
Commission, configure, convert or repair Festo products quickly and easily with videos from service2see.
Chapters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
00:19 Creating a program
05:39 Starting the program
Use “WebVisu” to commission the Festo servo press kit YJKP. This tutorial explains, how to create and start an easy program in the third step. This video shows the instruction at a YJKP-1,5 (force class 1.5 kN) and the control highness (master control) “WebVisu” as an example.
Commission, configure, convert or repair Festo products quickly and easily with videos from service2see.
Chapters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
00:18 Setting up the reference curve
01:29 Configuring monitoring
04:30 Running the program
Use “WebVisu” to commission the Festo servo press kit YJKP. This tutorial explains, how to evaluate the diagnosis in the fifth step. Therefore several successful and incorrect press fitting processes are shown and evaluated. This video shows the instruction at a YJKP-1.5 (force class 1.5 kN) and the control highness (master control) “WebVisu” as an example.
Commission, configure, convert or repair Festo products quickly and easily with videos from service2see.
Chapters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
00:17 Evaluating successful press process
01:26 Evaluating incorrect press process – Foreign part
02:48 Evaluating incorrect press process – Blockage
03:51 Evaluating incorrect press process – Signal fault