1. Fieldbus module
- Bus interface for communication in Ethernet-based networks with the higher-level controller
- With AP interface for communication with other AP participants (remote I/O, valve terminals)
- Module can be freely positioned on the terminal and independent of the 24 VDC system supply
- High data transmission rate, e.g. for I/O data from sensors, actuators, PLCs or process equipment
- Transmission of non-real-time critical information such as diagnostics and configuration information
- Sufficient Ethernet bandwidth to transmit real-time and non-real-time data at the same time
2. Intelligent end plate
Cost-effective and compact AP interface for additional AP participants
- Modular remote I/O CPA-AP-A
- Decentralised remote I/O modules CPX-AP-I
- Valve terminals with AP interface
Two variants of the 24 VDC power supply for the remote I/O modules
- Only 24 VDC output for additional AP participants (internal power supply from the terminal)
- 24 VDC power supply for the remote I/O terminal and voltage output for other AP participants (no power supply for installed valve terminals)
Real-time communication with 200 MBaud data rate and 250 μs cycle time
3. Input and output modules, IO-Link master
- All modules can be combined as required and can be flexibly connected in series
- Digital and analogue input and output modules up to 32-way possible in future
- IO-Link master for any IO-Link® devices at field level, e.g. electric drives, proportional pneumatic valves, vacuum generators, sensors
- Diagnostic LEDs for displaying the module's operating status and connected sensors or actuators
4. Interlinking blocks without power supply
- Transmitting voltage and communication from one module to the next and to the valve terminal
- Connecting the blocks to each other using self-forming angled fittings
- The connection can be loosened and retightened several times
5. Interlinking blocks with power supply
- Feeding in the 24 VDC supply voltage for I/O modules and the valve terminal (system and load voltage)
- Variant for additional supply of the load voltage of outputs and valves to create voltage zones
- Variant with 24 VDC forwarding supply for additional AP participants or external components
6. Pneumatic interface
- Connection between the remote I/O and the attached valve terminal
- Interface for VTUX and MPA-S with flat plate silencer, supply port and pilot air
- Interface for VTSA with module slot for any CPX-AP-A module, optional voltage supply and voltage forwarding, short-circuit shutdown and short-circuit diagnostics
7. Valve terminals
- Application-optimised valve terminal variants with full range of functions connected directly to the remote I/O
- VTUX: Highly modular
- MPA-S: Very compact
- VTSA: Sturdy and powerful
- Complete electrical and pneumatic terminal in IP65/67 for direct installation in the machine
- Separated system voltage and load voltage
8. Material selection
Modules and interlinking blocks are made of sturdy, high-quality polymer with fibreglass
- Flame retardant and halogen-free
- Suitable for welding applications
- High electromagnetic compatibility
- No epoxy resin filling, therefore environmentally friendly and easily recyclable
Metal is used wherever demanded by the relevant standards or when required for mounting
- Metal screw fittings and connections at the system supply
- Metal sleeves for shielding on module plug connectors
- End plates and mounting components, pneumatic interfaces